- Home
- Commercial Painting
- Intumescent Painting
- Intumescent Painting Merseyside
Need Passive Fire Protection for Your Steel Frame? We Sort It
Intumescent Painting Merseyside
Intumescent Coating Contractors for Offices, Warehouses and Factories
Intumescent Paint Installers for Steel Beams and Columns across Merseyside


- Constructionline Gold
- 15 years spraying
- 10-Year Peeling Guarantee
- Lowest Price Guarantee
- 24hr call outs
- Spray painting courses
Accredited & checkedOur accreditations and training schemes
- ConstructionlineGold



We are intumescent painting contractors working across Merseyside, and we protect structural steel in commercial buildings from the heat of a fire. Revamp Spray applies intumescent paint to beams, columns and frames so the steel keeps its strength for longer. If you need passive fire protection that passes inspection and looks tidy, you are in the right place.
Our team works with main contractors, building owners and fire engineers on offices, warehouses, factories, hotels, schools, shops and clinics. Our intumescent fire coating service covers the survey, the specification, the application and the paperwork. Our fire protection services come from one firm, start to finish.

Why Do Commercial Buildings Need Passive Fire Protection on Structural Steel?
What Happens to Structural Steel in a Fire?
Steel does not burn, but it weakens when it is exposed to high temperatures. Above about 400°C it loses strength fast, and at around 550°C common hot-rolled steel keeps only about 60% of its normal yield strength.
That loss can lead to structural failure. A sagging beam can pull a floor or a wall down with it. Good structural steel protection buys time for people to get out and for firefighters to work safely, and it helps keep the structural integrity of the whole building.
Fire and rescue services in England attended 13,111 fires in buildings other than dwellings in the year ending June 2026. In the year ending March 2026, the average response time to those fires was just over nine minutes. Steel exposed to high temperatures needs help fast, and intumescent coatings react to heat on their own, so fire protection starts before the fire crew arrives.
Which Commercial Properties Need Intumescent Fire Protection?
Any building with an exposed structural steel frame can need intumescent coatings. Typical jobs include office blocks, retail units, distribution warehouses, factories, hotels, hospitals, clinics, schools and restaurants. Car parks and plant rooms come up often too, and we coat the structural steelwork in both.
Most enquiries start with a trigger. A new build needs its steel protected before handover. A refurbishment adds a mezzanine floor, a change of use raises the required fire resistance period, or a fire risk assessment flags bare steel and the fire safety manager wants it fixed. We also take remedial calls where thin or damaged coating shows up at inspection.
Great Britain had 376,518 VAT and PAYE registered construction firms in the third quarter of 2025, and new construction work reached about £139.1 billion in 2025. That is a lot of steel needing the right fire protection and fire safety measures. It is also why we keep our process simple on busy construction projects.

What Is Intumescent Paint and How Does It Work?
What Is Intumescent Paint?
Intumescent paint is a thin coating that looks like normal paint until it is exposed to high temperatures. At around 200°C to 250°C it swells and forms a thick, foamy carbon layer. That layer thermally insulates the steel and slows how fast it heats up.
A typical thin film coat can swell to about 50 times its thickness. In simple terms, a 1mm coat can form a char around 50mm thick. Intumescent coatings need no power and no switch, because heat sets them off.
It is not magic, though. Intumescent coatings do not make a building fireproof. They form part of your passive fire protection, alongside fire doors, compartment walls and alarms. They delay the rise in steel temperature and help maintain structural integrity during a fire.
Intumescent paint works as a system, not a single tin. A full specification may include a compatible primer, an intumescent basecoat and a topcoat. If those layers do not match, the intumescent coatings may not perform as tested.
This is life safety work. We treat every coat as if a life depends on it, because one day it might. Thin film intumescent coatings also protect exposed structural steelwork while giving a neat finish, which looks better than boxing the steel in board.
How Many Minutes of Fire Resistance Can It Give?
Most systems give 30, 60 or 90 minutes of tested fire resistance. Suitable products and specifications can reach 120 minutes. Those minutes come from standard fire tests, so a 60 or 90 minute rating is not a promise that a real building stays up for exactly that long in every fire.
Coating thickness depends on more than the number of minutes. We look at the steel section, the section factor, the design temperature, the environment and the tested product. Slim sections heat up faster, so two beams that look alike can need different thicknesses.
Your fire engineer or structural designer sets the fire resistance you need. We build the dry film thickness schedule from that.

How Our Intumescent Painting Contractors Run Your Project From Survey to Sign-Off
Survey and Specification Come First
Every project starts with surveys, on site or from your drawings. We check steel sizes, the fire rating you need, access requirements and the state of any old coating. Then we match the project to a tested product and write the thickness schedule.
The Building Safety Act and Approved Document B guide fire safety regulations for most buildings in England, and the schedule has to meet them. That keeps your regulatory compliance and fire safety file clean. We work closely with your fire engineer and the principal contractor, so if the design changes, the schedule changes with it.
Surface Preparation and Application Conditions Matter
Bad prep ruins good paint. We clean the steel, remove loose rust and grease, and check the primer is sound and compatible. If the surface is poor, we treat it first.
Application conditions matter too. The steel surface should be at least 3°C above the dew point, so condensation cannot spoil adhesion or curing. We check the weather and the site each morning.
The substrate affects the product and the method. Most of our work is on structural steel, though we also check timber and concrete before we quote. Our crews follow health and safety procedures, including safe access and protection for other trades.
Should We Coat Your Steel On Site or Off Site?
We apply intumescent coatings on site for existing buildings, refurbishment and remedial work. On site work suits any project where the steel is already up and cannot move.
Off site application of intumescent coatings happens in a controlled workshop before the steel arrives. You get better control of conditions and quality, and it can speed up a new build programme. Steel coated off site still needs touch up after lifting and fixing, and we do that on site.
Thickness Checks, Records and Handover
We measure wet film while we spray and dry film once it cures. Both readings go on record against each steel section. That detailed schedule is the proof that the fire resistance was met.
You get full documentation at handover. That includes thickness records, product data, batch details and inspection notes. The same paper trail supports building control, insurers and regulatory compliance checks.
Busy sites cause damage. We handle touch up where other trades knock the intumescent coatings, and we repair older systems as part of our fire protection services.

Can Anyone Apply Intumescent Paint?
Anyone can buy a tin of intumescent paint, but not everyone should apply it. A coat that is too thin or badly mixed will not protect the steel when it counts.
Good intumescent paint contractors know the product data, measure film thickness, keep records and hand over full documentation. Many clients ask for third party accredited installers, and for good reason. Ask any contractor for proof of third party accredited status, training records and insurance.
If your tender asks for Constructionline Gold, tell us on the enquiry form and we will send our current details. As coating contractors, we also tell you when your fire protection plan needs a fire engineer first. We would rather say so early than fix it later.

Can You Overpaint Intumescent Paint?
Yes, but only with the right topcoat. Most systems need a compatible topcoat for colour, wear and moisture protection. Normal paint over the top can change how intumescent coatings react to heat, so never guess.
Check the manufacturer's data first. The wrong paint can cut the fire resistance even if it looks fine. If you want a colour change on exposed steel, tell us and we will match the topcoat to the system and to your RAL colour.

How Much Does Intumescent Painting Cost in Merseyside?
These are our rough prices based on recent projects. They are per square metre of steel surface and include materials and application of the intumescent coatings. Prices rise with the fire rating you need.
- 30 minutes: £15 to £28 per m2
- 60 minutes: £27 to £39 per m2
- 90 minutes: £40 to £60 per m2
- 120 minutes: £55 to £90 per m2
These prices are a rough guide and the actual cost varies from job to job. For an accurate quote, please use our contact form and we will price your steel properly.
Is Intumescent Paint Expensive?
Compared with normal paint, intumescent paint costs more. Compared with other fire protection for structural steel, intumescent coatings are often cost effective, especially on large exposed frames. Board casing takes more labour and more space.
Costs depend on the steel section, the dry film thickness, access and preparation. Small projects cost more per square metre because setup and travel spread over less steel.
Why Is Intumescent Paint So Expensive?
Intumescent coatings are tested, certified and applied thick. Fire rating, film thickness and the number of coats drive the bill, and thick coats need time to cure between layers.
Access and prep add cost too. Heavier steel sections usually need a thinner coat than slim ones, so the cheapest looking beam is not always the cheapest to protect with intumescent coatings. A cost effective plan starts with the right thickness on each section.
Is Intumescent Paint Worth It for Commercial Buildings?
For most commercial buildings, yes. Intumescent paint is thin, tested and keeps exposed steel looking clean. It is an effective method for meeting fire safety rules without hiding the structure, and it is a cost effective way to protect a steel frame.
This fire protection can fit tight programmes, because a thin coat can go on while other trades work nearby with the right controls. Your insurer and building control will want to see passive fire protection done properly, and we make that easy.

How Long Does Intumescent Paint Last?
Many intumescent coatings are tested for a working life of 10 years or more. Intumescent coatings inside dry, heated buildings often last far longer if they stay undamaged. Damp, chemicals, knocks and a failed topcoat shorten that life.
If you take on a building with an old system, we survey the intumescent coatings, measure the thickness and tell you what is sound. We repair what needs it. Regular checks keep structural fire protection working for as long as the building stands.

Why Choose Revamp Spray as Your Intumescent Paint Contractor Across Merseyside?
As intumescent coating contractors, we work across Merseyside, and our crews travel to your site. Our intumescent coatings services cover offices, warehouses, factories and other commercial properties of every size. You may see this work called fireproofing services, but we call it what it is: passive fire protection for structural steel.
We supply the whole system and apply it, so one team owns the result. Our aim is a cost effective plan and a clear price. We keep to the highest standards and to industry standards for application and records. Ask us for our accreditation details, including Constructionline Gold, and we will send them.
Our clients are building owners, facilities managers and main contractors. They want one point of contact, and we give them one. Our knowledge of tested systems means fewer delays and less rework.
We also spray cladding, floors and roofs as commercial painting contractors, but those jobs have their own services. This page is about fire protection and fire safety only.

Get a Free Quote for Fire Protection From Revamp Spray Today
Ready to start your fire protection project? Fill in our enquiry form with your project details and we will reply with a free, clear quote. We can also book a survey.
- Your steel schedule or drawings
- The fire rating you need
- The site address and access requirements
- Your start date and project programme
Contact our team today. Revamp Spray offers these services across Merseyside and the surrounding area, and we will take it from there.

Questions people ask us
Straight answers before you book. Something else? Call free on 0800 086 2742.
How much does intumescent painting cost in Merseyside?
Intumescent painting costs roughly £15 to £28 per m2 for 30 minutes, £27 to £39 per m2 for 60 minutes, £40 to £60 per m2 for 90 minutes and £55 to £90 per m2 for 120 minutes of fire resistance. That is a rough guide and the actual cost varies from job to job, so please use our contact form for an accurate quote.
How many minutes of fire resistance can intumescent paint give?
Intumescent paint can give 30, 60 or 90 minutes of tested fire resistance on most systems, and suitable products and specifications can reach 120 minutes. Your fire engineer or structural designer sets the rating you need, and we build the dry film thickness schedule from that.
How long does intumescent paint last?
Intumescent paint can last 10 years or more, as many intumescent coatings are tested for a working life of that length. Inside dry, heated buildings it often lasts far longer if it stays undamaged, while damp, chemicals, knocks and a failed topcoat shorten it. We survey older systems, measure the thickness and repair whatever needs attention.
Can you overpaint intumescent paint?
You can overpaint intumescent paint, but only with a topcoat that is compatible with the system. Normal paint over the top can change how the coating reacts to heat and cut the fire resistance, so check the manufacturer's data first. Tell us your RAL colour and we will match the topcoat to the system.
Can anyone apply intumescent paint?
Anyone can buy intumescent paint, but only trained contractors should apply it, because a coat that is too thin or badly mixed will not protect the steel. Ask any contractor for proof of third party accredited status, training records and insurance. Tell us on the enquiry form and we will send our current accreditation details.
Is intumescent paint worth it for commercial buildings?
Intumescent paint is worth it for most commercial buildings, because it is thin, tested and keeps exposed steel looking clean. It is a cost effective way to meet fire safety rules without hiding the structure, and our free quote shows your price before you commit.
Every part of Merseyside
We cover all of Merseyside. Pick your town or another service, or just send your postcode with your photos.
- Intumescent Painting LiverpoolMerseyside
- Intumescent Painting BirkenheadMerseyside
- Intumescent Painting St HelensMerseyside
- Intumescent Painting SouthportMerseyside
- Cladding Spraying MerseysideAlso in Merseyside
- Exterior House Painting MerseysideAlso in Merseyside
- Furniture Spraying MerseysideAlso in Merseyside
- Garage Door Spraying MerseysideAlso in Merseyside
- Kitchen Spray Painters MerseysideAlso in Merseyside
- On-Site Spraying MerseysideAlso in Merseyside
- Roof Painting MerseysideAlso in Merseyside
- Shop Front Spraying MerseysideAlso in Merseyside
- Spray Painting Courses MerseysideAlso in Merseyside
- uPVC Door Spraying MerseysideAlso in Merseyside
- uPVC Spraying MerseysideAlso in Merseyside
- uPVC Window Spraying MerseysideAlso in Merseyside